- (1) All habitable rooms and spaces must be provided with windows the total area of which must be not less than one-tenth of the floor area.
- (2) At least one-half of each required window must be able to open for ventilation purposes.
- (3) Every sleeping room must have at least one operable window or door for emergency escape or rescue directly opening to an outside area to provide a clear escape away from the building.
(4) Escape or rescue windows must have:
- (a) A minimum net clear openable area of five point seven square feet; and
- (b) A finished sill height not more than forty-four inches above the floor.
(c) The following minimum net clear openable dimensions:
- (i) The height dimension of twenty-four inches; and
- (ii) The width dimension of twenty inches.
- (5) All operable window openings must be screened with sixteen-mesh material.
[Statutory Authority: RCW 70.114A.081. WSR 99-03-065, § 246-359-500, filed 1/18/99, effective 2/18/99.]