Wash. Admin. Code § 246-359-300
(5) The department of health will allow spans using other wood species or grade or other load conditions when accompanied by structural calculations prepared by a structural engineer or architect.
| Table 300-AWestern Wood Products Table for Hem-Fir #2Ceiling Joists 10# Dead Load | ||
| Ceiling Joist Size | Spacing—inches on center | Span—feet-inches |
| 2 x 6 | 12 | 14-5 |
| 2 x 6 | 16 | 12-8 |
| 2 x 6 | 24 | 10-4 |
| 2 x 8 | 12 | 18-6 |
| 2 x 8 | 16 | 16-0 |
| 2 x 8 | 24 | 13-1 |
| 2 x 10 | 12 | 22-7 |
| 2 x 10 | 16 | 19-7 |
| 2 x 10 | 24 | 16-0 |
| 2 x 12 | 12 | 26-3 |
| 2 x 12 | 16 | 22-8 |
| 2 x 12 | 24 | 18-6 |
[Statutory Authority: Chapter 70.114A RCW and RCW 43.70.334 through 43.70.340. WSR 15-13-091, § 246-359-300, filed 6/15/15, effective 1/1/16. Statutory Authority: RCW 70.114A.081. WSR 99-03-065, § 246-359-300, filed 1/18/99, effective 2/18/99.]