9 Va. Admin. Code § 5-510-190
A. The permittee shall not cause or allow to be discharged into the atmosphere from any covered emissions units any visible emissions in excess of the limits specified in subdivisions 1, 2 and 3 of this subsection.
2. Equipment manufactured or fabricated after August 31, 1983, shall comply with 40 CFR Part 60, Subpart 000, 9VAC5-50-260 and the following standards:
B. The permittee shall not cause or allow to be discharged into the atmosphere from any covered emissions units any particulate matter in excess of the limits specified in subdivisions 1 and 2 of this subsection.
1. Fabric filter exhausts controlling equipment manufactured or fabricated on or prior to August 31, 1983, shall not exceed the following limits:
b. For facilities located in the remainder of the Commonwealth, 0.05 grains/dscf (ref: Article 14 (9VAC5-40-1820 et seq.) of 9VAC5 Chapter 40).
TABLE 510A
Process Weight Rate Maximum Allowable Emission Rate
Lb/Hr Tons/Hr Lb/HR
100 0.050 0.46
150 0.075 0.66
200 0.100 0.85
250 0.125 1.03
300 0.150 1.20
350 0.175 1.35
400 0.200 1.50
450 0.225 1.63
500 0.250 1.77
550 0.275 1.85
600 0.300 2.01
650 0.325 2.12
700 0.350 2.24
750 0.375 2.34
800 0.400 2.43
850 0.425 2.53
900 0.450 2.62
950 0.475 2.72
1000 0.500 2.80
1100 0.55 2.97
1200 0.60 3.12
1300 0.65 3.26
1400 0.70 3.40
1500 0.75 3.54
1600 0.80 3.66
1700 0.85 3.79
1800 0.90 3.91
1900 0.95 4.03
2000 1.00 4.14
2100 1.05 4.24
2200 1.10 4.34
2300 1.15 4.44
2400 1.20 4.55
2500 1.25 4.64
2600 1.30 4.74
2700 1.35 4.84
2800 1.40 4.92
2900 1.45 5.02
3000 1.50 5.10
3100 1.55 5.18
3200 1.60 5.27
3300 1.65 5.36
3400 1.70 5.44
3500 1.75 5.52
3600 1.80 5.61
3700 1.85 5.69
3800 1.90 5.77
3900 1.95 5.85
4000 2.00 5.93
4100 2.05 6.01
4200 2.10 6.08
4300 2.15 6.15
4400 2.20 6.22
4500 2.25 6.30
4600 2.30 6.37
4700 2.35 6.45
4800 2.40 6.52
4900 2.45 6.60
5000 2.50 6.67
5500 2.75 7.03
6000 3.00 7.37
6500 3.25 7.71
7000 3.50 8.05
7500 3.75 8.39
8000 4.00 8.71
8500 4.25 9.03
9000 4.50 9.36
9500 4.75 9.67
10000 5.00 10.00
11000 5.50 10.63
12000 6.00 11.28
13000 6.50 11.89
14000 7.00 12.50
15000 7.50 13.13
16000 8.00 13.74
17000 8.50 14.36
18000 9.00 14.97
19000 9.50 15.58
20000 10.00 16.19
30000 15.00 22.22
40000 20.00 28.30
50000 25.00 34.30
60000 or more 30.00 or more 40.00
C. Fugitive dust/emissions controls shall include the following or equivalent as a minimum:
D. In order to operate under the authority of this permit, a nonmetallic mineral processing facility shall not exceed any of the following:
§ 10.1-1308 of the Code of Virginia.
Derived from Virginia Register Volume 19, Issue 3, eff. December 1, 2002.