9 Va. Admin. Code § 25-151-340
B. Benchmark monitoring and reporting requirements. Metal fabricating facilities are required to monitor their stormwater discharges for the pollutants of concern listed in Table 340.
| Table 340 Sector AA – Benchmark Monitoring Requirements | |
| Pollutants of Concern | Benchmark Concentration |
| Fabricated Metal Products Except Coating (SIC Codes 3411-3471, 3482-3499, 3911-3915) | |
| Total Recoverable Aluminum | 1,100 µg/L |
| Total Recoverable Zinc | 120 µg/L |
| Total Recoverable Copper | 13 μg/L |
| Fabricated Metal Coating and Engraving (SIC Code 3479) | |
| Total Recoverable Zinc | 120 µg/L |
§ 62.1-44.15 of the Code of Virginia; § 402 of the Clean Water Act; 40 CFR Parts 122, 123, and 124.
Derived from Virginia Register Volume 15, Issue 9, eff. June 30, 1999; amended, Virginia Register Volume 20, Issue 16, eff. July 1, 2004; Volume 25, Issue 19, eff. June 24, 2009; Volume 30, Issue 11, eff. July 1, 2014; Volume 35, Issue 19, eff. July 1, 2019; Volume 40, Issue 15, eff. July 1, 2024.