- A. When electric detonators are used, an acceptable blaster's galvanometer or blaster's multi-meter shall be used to test detonators, firing lines, series circuits, and total circuit resistance prior to firing.
- B. Electric detonators of different brands shall not be used in the same blast.
C. Except when being tested with an acceptable instrument:
- 1. Electric detonators shall be kept shunted until they are connected into the series circuit;
- 2. Series circuits shall be kept shunted until they are connected onto the firing line; and
- 3. Firing lines shall be kept shunted until immediately before blasting.
- D. Blasting machines or other acceptable power sources shall be suitable for the number of electric detonators to be fired and for the type of circuits to be used.
- E. When electric detonators are used, sources of stray current to the blasting area shall be de-energized. Blasting activities shall be stopped immediately if stray current or static electricity in amounts sufficient to cause a premature detonation are encountered.