13 Va. Admin. Code § 5-63-290
A. Change the exception to Section 1804.6 of the IBC to read:
Exception: Compacted fill material less than 12 inches (305 mm) in depth need not comply with an approved report, provided it is a natural non-organic material that is not susceptible to swelling when exposed to moisture and it has been compacted to a minimum of 90% Modified Proctor in accordance with ASTM D1557. The compaction shall be verified by a qualified inspector approved by the building official. Material other than natural material may be used as fill material when accompanied by a certification from an RDP and approved by the building official.
B. Add an exception to Section 1808.1 of the IBC to read:
Exception: One-story detached accessory structures not exceeding 256 square feet (23.78m2) of building area, provided all of the following conditions are met: