- A. Drinking water systems that utilize one or more Class III wells shall be capable of supplying water in adequate quantity for the intended usage. Systems with a capacity under three gallons per minute shall have ability to produce and store 150 gallons per bedroom per day and be capable of delivering a sustained flow of five gallons per minute per connection for 10 minutes for ordinary residential use. Systems with a capacity of three gallons per minute or more do not require additional storage.
- B. The certified water well systems provider shall certify the storage capacity and the yield of the well on the Uniform Water Well Completion Report.
Statutory Authority
§§ 32.1-12 and 32.1-176.4 of the Code of Virginia.
Historical Notes
Derived from Virginia Register Volume 28, Issue 22, eff. August 16, 2012; amended, Virginia Register Volume 41, Issue 4, eff. November 6, 2024.