- (1) The following amendment is adopted as an amendment to the IRC for the Park City Corporation, Appendix P, of the 2006 IRC is adopted.
(2) The following amendments are adopted as amendments to the IRC for Park City Corporation and Park City Fire District:
- (a) IRC, Section R905.7, is deleted and replaced with the following: "R905.7 Wood shingles. The installation of wood shingles shall comply with the provisions of this section. Wood roof covering is prohibited in areas with a combined rating of more than 11 using the following tables with a score of 9 for weather factors.TABLEWILDFIRE HAZARD SEVERITY SCALERATINGSLOPEVEGETATION1less than or equal to 10%Pinion-juniper210.1 - 20%Grass-sagebrush3greater than 20%Mountain brush or softwoodsPROHIBITION/EXEMPTION TABLERATINGWOOD ROOF PROHIBITIONless than or equal to 11wood roofs are allowedgreater than or equal to 12wood roofs are prohibited"
- (b) IRC, Section R905.8, is deleted and replaced with the following: "R905.8 Wood Shakes. The installation of wood shakes shall comply with the provisions of this section. Wood roof covering is prohibited in areas with a combined rating of more than 11 using the following tables with a score of 9 for weather factors.TABLEWILDFIRE HAZARD SEVERITY SCALERATINGSLOPEVEGETATION1less than or equal to 10%Pinion-juniper210.1 - 20%Grass-sagebrush3greater than 20%Mountain brush or softwoodsPROHIBITION/EXEMPTION TABLERATINGWOOD ROOF PROHIBITIONless than or equal to 11wood roofs are allowedgreater than or equal to 12wood roofs are prohibited"
- (c) Appendix K is adopted.
Enacted by Chapter 14, 2011 General Session