(1) The department allows the following methods for sterilization:
(a)(i) Pressure Steam.
- (ii) Expose the material to treatment by steam at 15 PSI (.104 mPA) for 30 minutes or 20 PSI (.0138 mPA) for 20 minutes.
- (iii) The gauge for registering steam pressure shall be visible from the outside of the room or chamber.
(b)(i) Streaming Steam.
- (ii) Two applications of streaming steam maintained for one hour each, applied at intervals using not less than six nor more than 24 hours.
- (iii) When streaming steam is employed, the valved outlets shall be provided near the bottom and the top of the room or chamber.
(c)(i) Heat.
- (ii) A temperature of 235 degrees F held for two hours within a closed container.
- (2) Upon request, the department may approve other methods of sterilization.
KEY: inspections, labeling, quality control, registration, bedding, upholstered furniture, law labels, filling material
Date of Last Change: December 22, 2025
Notice of Continuation: May 7, 2025
Authorizing, and Implemented or Interpreted Law: 4-10-103