Utah Admin. Code R652-122-1500
(2) Engines and water tenders used on private wildland fires within the county's jurisdiction will meet the standard for the type of equipment plus appropriate hand tools and water handling equipment as determined by the National Wildfire Coordinating Group.
TABLE 1EnginesComponentType 1Type 2Type 3Pump Rating - gpm1,000+ @ 150 psi250+ @ 150 psi150+ @ 250 psiTank Capacity - gal400+400+500+Hose 2.5 inch1,200 ft1,000 ft--Hose 1.5 inch400 ft500 ft500 ftHose 1 inch----500 ftLadders48 ft48 ft--Master Stream -- gpm500----Personnel - minimum432
ComponentType 4Type 5Type 6Pump Rating - gpm50 @ 100 psi50 @ 100 psi30 @ 100 psiTank Capacity - gal750+400 - 750150 - 400Hose 2.5 inch------Hose 1.5 inch300 ft300 ft300 ftHose 1 inch300 ft300 ft300 ftLadders------Master Stream -- gpm------Personnel - minimum222
TABLE 2Water TendersComponentType 1Type 2Type 3Tank Capacity - gal5,000+2,500+1,000+Pump Capacity - gpm300+200+200+Off Load Capacity - gpm300+200+200+Max Refill Time -- min302015Personnel tactical/nontactical2/12/12/1
KEY: minimum standards, wildland urban interface, cooperative agreements
Date of Last Change: June 21, 2024
Notice of Continuation: January 8, 2026
Authorizing, and Implemented or Interpreted Law: 65A-8-203