(1)(a) The operator shall ensure that the minimum number of plumbing fixtures are provided to each modern camp in a service building according to Table 1.
- (b) Where a camp is not used exclusively by one gender, the number of fixtures shall be based on 50% of the total number of occupants being male and 50% being female.
- (2) Showers and sinks shall be provided with hot and cold potable water.
- (3) A sink shall be located either in the same room as each toilet, or immediately adjacent to the service building.
- (4) For any toilet room intended to be used by males only, a urinal may be substituted for a toilet for up to half of the required number of toilets as long as the urinal is installed in the same location as the toilets.
- (5) A service building shall be located not less than 15 feet and not more than 300 feet from any living and camping space served, unless integrated into a permanent building at a modern camp.
- (6) Soap and toilet tissue in a suitable dispenser, and a waste receptacle with a lid shall be provided in each service building.
- (7) Clean individual disposable towels, or other alternate hand drying method approved by the local health officer, shall be provided at each sink.
(8) The operator shall ensure that each service building is maintained in a clean and sanitary condition.
TABLE 1Required Minimum Plumbing Fixtures for Modern CampsPlumbing FixturesRatio of Plumbing Fixtures for Number of Camp Occupants*or fraction thereofMalesFemalesBoth GendersToilets1:40*1:25*--Sinks1:35*1:35*--Showers1:35*1:35*--Drinking Fountains----1:300Service Sink----1 per service buildingPotable Water Faucet----1 per service building
KEY: camp, campground, public health, recreation areas
Date of Last Change: November 8, 2023
Notice of Continuation: October 21, 2021
Authorizing, and Implemented or Interpreted Law: 26B-1-202; 26B-7-402