- (a) A description of the containment system to demonstrate compliance with Section R315-264-175. Show at least the following:
- (1) Basic design parameters, dimensions, and materials of construction.
- (2) How the design promotes drainage or how containers are kept from contact with standing liquids in the containment system.
- (3) Capacity of the containment system relative to the number and volume of containers to be stored.
- (4) Provisions for preventing or managing run-on.
(5) How accumulated liquids can be analyzed and removed to prevent overflow.
- (b) For storage areas that store containers holding wastes that do not contain free liquids, a demonstration of compliance with Subsection R315-264-175(c), including:
- (1) Test procedures and results or other documentation or information to show that the wastes do not contain free liquids; and
(2) A description of how the storage area is designed or operated to drain and remove liquids or how containers are kept from contact with standing liquids.
- (c) Sketches, drawings, or data demonstrating compliance with Section R315-264-176, location of buffer zone and containers holding ignitable or reactive wastes, and Subsection R315-264-177(c), location of incompatible wastes, where applicable.
- (d) Where incompatible wastes are stored or otherwise managed in containers, a description of the procedures used to ensure compliance with Subsections R315-264-177(a) and (b), and Subsections R315-264-17(b) and (c).
- (e) Information on air emission control equipment as required in Section R315-270-27.
Except as otherwise provided in Section R315-264-170, owners or operators of facilities that store containers of hazardous waste shall provide the following additional information:
KEY: hazardous waste
Date of Last Change: November 17, 2025
Notice of Continuation: December 11, 2025
Authorizing, and Implemented or Interpreted Law: 19-6-105; 19-6-106