Utah Admin. Code R315-261-196
(2) If the material released was to a secondary containment system, all released materials shall be removed within 24 hours or in as timely a manner as is possible to prevent harm to human health and the environment.
(2) Remove, and properly dispose of, any visible contamination of the soil or surface water.
(2) A leak or spill of hazardous secondary material is exempted from the requirements of Subsection R315-261-196(d) if it is:
(i) Less than or equal to a quantity of 1 pound, and
(3) Within 30 days of detection of a release to the environment, a report containing the following information shall be submitted to the Director:
(i) Likely route of migration of the release;
(4) If the source of the release was a leak to the environment from a component of a tank system without secondary containment, the remanufacturer or other person that stores or treats the hazardous secondary material shall provide the component of the system from which the leak occurred with secondary containment that satisfies the requirements of Section R315-261-193 before it can be returned to service, unless the source of the leak is an aboveground portion of a tank system that can be inspected visually. If the source is an aboveground component that can be inspected visually, the component shall be repaired and may be returned to service without secondary containment as long as the requirements of Subsection R315-261-196(f) are satisfied. Additionally, if a leak has occurred in any portion of a tank system component that is not readily accessible for visual inspection, e.g., the bottom of an inground or onground tank, the entire component shall be provided with secondary containment in accordance with Section R315-261-193 prior to being returned to use.
(f) Certification of major repairs. If the remanufacturer or other person that stores or treats the hazardous secondary material has repaired a tank system in accordance with Subsection R315-261-196(e), and the repair has been extensive, e.g., installation of an internal liner; repair of a ruptured primary containment or secondary containment vessel, the tank system shall not be returned to service unless the remanufacturer or other person that stores or treats the hazardous secondary material has obtained a certification by a qualified Professional Engineer that the repaired system is capable of handling hazardous secondary materials without release for the intended life of the system. This certification shall be kept on file at the facility and maintained until closure of the facility.
Note 1 to Section R315-261-196: The Director may, on the basis of any information received that there is or has been a release of hazardous secondary material or hazardous constituents into the environment, issue an order under RCRA section 7003(a) requiring corrective action or such other response as deemed necessary to protect human health or the environment.
Note 2 to Section R315-261-196: 40 CFR part 302 may require the owner or operator to notify the National Response Center of certain releases.
A tank system or secondary containment system from which there has been a leak or spill, or which is unfit for use, shall be removed from service immediately, and the remanufacturer or other person that stores or treats the hazardous secondary material shall satisfy the following requirements:
KEY: hazardous waste
Date of Last Change: November 17, 2025
Notice of Continuation: December 11, 2025
Authorizing, and Implemented or Interpreted Law: 19-6-105; 19-6-106