- (1) Rule R313-34 shall apply to panoramic irradiators that have either dry or wet storage of the radioactive sealed sources; underwater irradiators in which both the source and the product being irradiated are under water; and irradiators whose dose rates exceed 5 grays (500 rads) per hour at 1 meter from the radioactive sealed sources in air or in water, as applicable for the irradiator type.
- (2) The requirements of Rule R313-34 shall not apply to self-contained dry-source-storage irradiators in which both the source and the area subject to irradiation are contained within a device and are not accessible by personnel, medical radiology or teletherapy, the irradiation of materials for nondestructive testing purposes, gauging, or open-field agricultural irradiations.
KEY: irradiators, survey, radiation, radiation safety
Date of Last Change: January 17, 2023
Notice of Continuation: October 19, 2021
Authorizing, and Implemented or Interpreted Law: 19-3-104(4); 19-3-104(7)