(1) The owner or operator shall:
- (a) Store all VOC-containing coatings, thinners, and cleaning materials in closed containers;
- (b) Minimize spills of VOC-containing coatings, thinners, and cleaning materials;
- (c) Clean up spills immediately;
- (d) Convey any coatings, thinners, and cleaning materials in closed containers or pipes;
- (e) Close mixing vessels that contain VOC coatings and other materials except when specifically in use; and
- (f) Minimize usage of solvents during cleaning of storage, mixing, and conveying equipment.
(2) No person shall apply any coating unless the coating application method achieves a demonstrated 65% transfer efficiency.
- (a) Electrostatic application;
- (b) Electrodeposition;
- (c) Brush coat;
- (d) Flow coat;
- (e) Roll coat;
- (f) Dip coat;
- (g) Continuous coating;
(h) High-volume, low-pressure (HVLP) spray; or
- (i) Other application method capable of achieving 65% or greater transfer efficiency, as certified by the manufacturer.
The following applications achieve a minimum of 65% transfer efficiency and shall be operated in accordance with the manufacturers specifications:
- (3) Solvent cleaning operations shall be performed using cleaning materials having a VOC composite vapor pressure no greater than 1 mm Hg at 20 degrees Celsius, unless an add-on control device is used as specified in R307-346-7.
KEY: air pollution, emission controls, surface coating, metal furniture
Date of Last Change: December 6, 2017
Notice of Continuation: February 1, 2023
Authorizing, and Implemented or Interpreted Law: 19-2-104(1)(a)