Utah Admin. Code R307-170-6
(1) Fossil Fuel Fired Steam Generators.
(a) A continuous monitoring system for the measurement of opacity shall be installed, calibrated, maintained, and operated on any fossil fuel fired steam generator of greater than 250 million BTU per hour for each boiler except where:
(2) Nitric Acid Plants.
Each nitric acid plant of greater than 300 tons per day production capacity, the production capacity being expressed as 100 percent acid, and located in an Air Quality Control Region where the director has specifically determined that a control strategy for nitrogen dioxide is necessary to attain the national standard, shall install, calibrate, maintain, and operate a continuous monitoring system for the measurement of nitrogen oxides for each nitric acid producing installation.
(3) Sulfuric Acid Plants - Burning and Production.
Each sulfuric acid plant of greater than 300 tons per day production capacity, the production being expressed as 100 percent acid, shall install, calibrate, maintain and operate a continuous monitoring system for the measurement of sulfur dioxide for each sulfuric acid producing installation within such plant.
(4) Petroleum Refineries - Fluid Bed Catalytic Cracking Unit Catalyst Regenerator.
Each catalyst regenerator for fluid bed catalytic cracking units of greater than 20,000 barrels per day fresh feed capacity shall install, calibrate, maintain and operate a continuous monitoring system for the measurement of opacity.
KEY: air pollution, monitoring, continuous monitoring
Date of Last Change: February 8, 2008
Notice of Continuation: December 7, 2022
Authorizing, and Implemented or Interpreted Law: 19-2-101; 19-2-104(1)(c); 19-2-115(3)(b); 40 CFR 60