Leachate-collection and associated leachate-removal systems shall be:
- (1) constructed of materials that are chemically resistant to the leachate expected to be generated;
- (2) of sufficient strength and thickness to prevent collapse under the pressures exerted by overlying wastes, waste cover materials, and by any equipment used at the landfill; and
(3) designed and operated to function through the scheduled closure and post-closure care period of the landfill considering the following factors:
- (A) estimated rate of leachate removal;
- (B) capacity of sumps;
- (C) pipe material and strength, if used;
- (D) pipe network spacing and grading, if used;
- (E) collection sump materials and strength;
- (F) drainage media specifications and performance; and
- (G) demonstration that pipes and perforations will be resistant to clogging and can be cleaned.
Source Note:The provisions of this §330.333 adopted to be effective March 27, 2006, 31 TexReg 2502.