(a) Equipment may only be removed from service by a registered inspector using the following procedures:
- (1) Hydraulic elevators must be brought to the lowest landing with the doors closed and the main line disconnect switch locked in the off position.
- (2) Electric elevators must be brought to the top landing, with the doors closed and the main line disconnect switch locked in the off position.
- (3) Escalators must have their main line disconnect switch locked in the off position and each end of the escalator barricaded.
- (4) All other related equipment must have their main line disconnect switch locked in the off position.
(b) Equipment removed from service may only have the power restored:
- (1) by a registered Contractor performing upgrades or alterations;
- (2) by a registered Inspector performing an Acceptance or Annual Inspection; or
- (3) with approval of the Department.
- (c) All other related equipment must have their main line disconnect switch locked in the off position.
- (d) Equipment removed from service shall be returned to service after performing an approved acceptance or annual inspection performed in accordance with §74.66.
Source Note:The provisions of this §74.105 adopted to be effective February 15, 2016, 41 TexReg 962.