(1) (a) A log of all malfunctions, startups, and shutdowns resulting in emissions excess of the standards in Division 1200-03 or any permit issued thereto must be kept at the plant. This log must record at least the following:
- 1. Stack or emission point involved.
- 2. Time malfunction, startup, or shutdown began and/or when first noticed.
- 3. Type of malfunction and/or reason for shutdown.
- 4. Time startup or shutdown was complete or time the air contaminant source returned to normal operation.
- 5. The company employee making entry on the log must sign, date, and indicate the time of each log entry.
- (b) The information under parts (a)1. and 2. of this paragraph must be entered into the log by the end of the shift during which the malfunction or startup began.
- (c) All information shall be entered in the log no later than twenty-four (24) hours after the startup or shutdown is complete, or the malfunction has ceased or has been corrected.
- (d) Any later discovered corrections can be added in the log as footnotes with the reason given for the change.
- (2) Reserved.
Authority: T.C.A. §§ 4-5-201, et seq.; 68-201-101, et seq.; and 68-201-105. Administrative History: Original rule filed February 5, 1979; effective March 21, 1979. Amendment filed September 22, 1988; effective November 6, 1988. Repeal and new rule filed July 13, 1994; effective September 26, 1994. Amendment filed March 21, 2013; effective June 19, 2013.