ARSD 74:51:01:44
The criteria of parameters for domestic water supply waters and their allowable variations that are not included under § 74:51:01:55 and Appendix B, unless set under § 74:51:01:24, are as found in the following table:
Parameter
Criteria
Unit of Measure
Special Conditions
Total dissolved solids
< 1,000
mg/L
30-day average
< 1,750
mg/L
daily maximum
Nitrates as N
< 10
mg/L
daily maximum
pH
> 6.5 - < 9.0
units
Total Coliform
< 5,000
/100 mL
geometric mean of a minimum of 5 samples during separate 24-hour periods for a 30-day period and may not exceed this value in more than 20 percent of the samples examined in the same 30-day period
< 20,000
/100 mL
in any one sample
Barium
< 1.0
mg/L
daily maximum
Chloride
< 250
mg/L
30-day average
< 438
mg/L
daily maximum
Fluoride
< 4.0
mg/L
daily maximum
Sulfate
< 500
mg/L
30-day average
< 875
mg/L
daily maximum
Total Petroleum Hydrocarbons
< 1.0
mg/L
daily maximum
Source: SL 1975, ch 16, § 1; 4 SDR 32, effective December 4, 1977; transferred from § 34:04:02:33, effective July 1, 1979; 10 SDR 145, effective July 4, 1984; 13 SDR 129, 13 SDR 141, effective July 1, 1987; 14 SDR 86, effective December 24, 1987; 19 SDR 111, effective January 31, 1993; transferred from § 74:03:02:33, July 1, 1996; 24 SDR 10, effective July 20, 1997; 35 SDR 253, effective May 12, 2009 ; 47 SDR 110, effective April 27, 2021 .
General Authority: SDCL 34A-2-10, 34A-2-11, 34A-2-93.
Law Implemented: SDCL 34A-2-10 , 34A-2-11.
Prior versions effective: 2009-05-12.