ARSD 44:73:12:16
A facility shall locate drinking fountains, telephone booths, fire extinguisher cabinets, and vending machines so that they do not project into the required width of exit corridors. Handrails installed in corridors must return to the wall at the ends. Handrails must be installed with the top thirty-four to thirty-eight inches from the floor and with one and one-half inch spacing between the wall and the handrail.
Source: SL 1975, ch 16, § 1; 6 SDR 93, effective July 1, 1980; 14 SDR 81, effective December 10, 1987; 22 SDR 70, effective November 19, 1995; 26 SDR 96, effective January 23, 2000; transferred from § 44:04:13:09 , 42 SDR 51, effective October 13, 2015 ; 51 SDR 53, effective November 11, 2024 .
General Authority: SDCL 34-12-13 .
Law Implemented: SDCL 34-12-13 .
Prior versions effective: 2015-10-13.