All Nursing Mothers Rooms created under this chapter must:
- (1) Be in a location that complies with the Americans with Disabilities Act of 1990 (ADA) (42 U.S.C.A. § § 12101-12213). All accessories, equipment, furniture and casework shall be provided and installed to comply with ADA requirements, including but not limited to accessibility clearances and regulations.
- (2) Have a minimum square footage of 80 net useable square feet.
- (3) Have a privacy latch or locking door hardware, or both so that the door can be locked from the inside.
- (4) Provide visual privacy to the space by modifying or covering windows, sidelights and doors.
- (5) Provide sound privacy to the space to minimize sound transmission into adjacent spaces, including using sound attenuation insulation if possible.
- (6) Include a chair and table, countertop or desk. The chair must be upholstered, cushioned, have armrests, a high back and be of standard seating height.
- (7) Provide at least one electrical duplex outlet next to where the individual will be seated.
- (8) Contain a waste receptacle.
- (9) Meet standard office level illumination and ventilation requirements.
- (10) Not be a restroom, toilet stall, storage room or janitor’s closet.