(c) Wire rope shall be removed from service when any of the following conditions exists:
- (1) In hoisting ropes, six randomly distributed broken wires in one rope lay or three broken wires in one strand in one rope lay.
- (2) Abrasion, scrubbing, flattening, or peening, causing loss of more than 1/3 of the original diameter of the outside wires.
- (3) Evidence of any heat damage resulting from a torch or any damage caused by contact with electrical wires.
- (4) Reduction from nominal diameter of more than 3/64 inch for diameters up to and including 3/4 inch; 1/16 inch for diamerers 7/8 to 1 1/8 inches; and 3/32 inch for diameters 1 1/4 to 1 1/2 inches.