34 Pa. Code § 7.274
Shaftway clearances shall conform to the following:
(1) New freight elevators, except handpower, sidewalk, plunger, hydraulic or plunger hydrosteam types, shall be so constructed that the minimum clearance between the highest point of the elevator car crosshead and the lowest point of any overhead construction when the car platform is flush with the upper terminal landing and the minimum clearance between the lowest point of such elevator car bottom of safety plank and the pit floor or top of any construction contained therein when the elevator car is at the lowest terminal landing shall conform to the following table:
| Location | Allowance in Feet | ||
| Overrun | Clear | Total | |
| Top of shaftway | 2 | 2 | 4 |
| Bottom of shaftway | 2 | 2 | 4 |
The provisions of this § 7.274 amended through December 21, 1967.
This section cited in 34 Pa. Code § 7.291 (relating to general); 34 Pa. Code § 7.295 (relating to hydraulic freight elevators); 34 Pa. Code § 7.298 (relating to gravity elevators); and 34 Pa. Code § 7.300 (relating to electric or oil-electric platform elevators).