34 Pa. Code § 50.23
(b) The units of width table shall be as follows:
| Units | Doorways (Width in inches) | Stairs & Corridors (Width in inches) |
| 1 1/2 | 32 | 36 |
| 2 | 40 | 44 |
| 2 1/2 | 50 | 50 |
An additional 10 inches shall be required for each 1/2 unit of width above 2 1/2 units. Credit for units of width shall not be given for a fractional part other than 1/2 unit.
(e) The following table lists the maximum permissible square feet per person for the purpose of determining the minimum number of units of exit:
1. Net floor area shall be taken to mean all usable floor space, including all areas occupied by equipment or furnishings, but not including corridors, toilet rooms, and such other accessory rooms as may be provided.
2. Bleachers or benches without arms between seats shall be computed on the basis of not more than one person for every 18 inches in length of the bleachers or bench.
This section cited in 34 Pa. Code § 51.23 (relating to means of egress capacity); 34 Pa. Code § 52.23 (relating to means of egress capacity); 34 Pa. Code § 53.23 (relating to means of egress capacity); 34 Pa. Code § 54.23 (relating to means of egress capacity); 34 Pa. Code § 55.23 (relating to means of egress capacity); 34 Pa. Code § 56.23 (relating to means of egress capacity); 34 Pa. Code § 57.23 (relating to means of egress capacity); 34 Pa. Code § 58.23 (relating to means of egress capacity); and 34 Pa. Code § 59.23 (relating to means of egress capacity).