(c) Type of protector. Under approved conditions for use of respiratory protectors as specified in § 35.61 (relating to exceptions to booth requirements), various types of respiratory protectors shall be used pursuant to the following requirements:
- (1) When health hazardous substances used in spray coating are in the particulate form, the respiratory protectors used shall be of the filter type.
- (2) When health hazardous substances are in the form of gas or vapor the respiratory protector shall contain gas or vapor absorbents or adsorbents such as activated charcoal.
- (3) When health hazardous substances are in the form of both particulate matter and gases or vapors, the respiratory protector shall contain both a mechanical filter and an absorbent or adsorbent.
- (4) A positive pressure air respirator may be substituted for any of the respiratory protectors specified in paragraphs (1)—(3).