(a) A site-specific installation permit application must contain maps and plans of the proposed storage tank system or facility site showing all of the following:
- (1) The boundaries for the proposed facility site.
- (2) The location of the proposed storage tanks.
- (3) The location and names of public roads within or adjacent to the proposed facility site.
- (4) The location of proposed monitoring wells.
- (5) The municipality and county.
- (6) The elevation and location of test borings and core samples.
- (7) The ownership, if known, location and extent of known workings of active, inactive and abandoned underground mines including mine openings within the proposed permit site.
- (8) Streams, lakes or surface watercourses located on or adjacent to the proposed permit site.
- (9) The location and ownership of public or private groundwater supplies within 2,500 feet of the proposed permit site.
- (10) Sufficient slope measurements to adequately represent the existing land surface configuration of the proposed permit site.
- (b) Maps, plans and cross sections required by this section shall be accurately surveyed and on a scale satisfactory to the Department, not less than 1 inch to 400 feet and in a manner satisfactory to the Department. The maps, plans and cross sections shall be prepared by a Pennsylvania registered professional engineer, Pennsylvania registered land surveyor or Pennsylvania registered professional geologist with assistance from experts in related fields.
Source
The provisions of this § 245.233 amended December 21, 2018, effective December 22, 2018, 48 Pa.B. 7875. Immediately preceding text appears at serial page (331037).
Cross References
This section cited in 25 Pa. Code § 245.232 (relating to general requirements).