25 Pa. Code § 129.136
(a) Applicability. This section applies to the owner or operator of a reciprocating compressor or centrifugal compressor subject to § 129.131(a)(4) (relating to general provisions and applicability) that meets the following:
(b) VOC emissions control requirements for a reciprocating compressor. Beginning December 2, 2023, the owner or operator of a reciprocating compressor subject to this section shall meet one of the following:
(1) Replace the reciprocating compressor rod packing on or before one of the following:
(i) The reciprocating compressor has operated for 26,000 hours. The number of hours of operation must be continuously monitored beginning on the later of:
(ii) The reciprocating compressor has operated for 36 months. The number of months of operation must be continuously monitored beginning on the later of:
(c) VOC emissions limitation and control requirements for a centrifugal compressor. Except as specified in subsection (d), the owner or operator of a centrifugal compressor subject to this section shall perform the following:
(d) Exemptions. Subsection (c) does not apply to the owner or operator of a centrifugal compressor that meets the following:
(e) Recordkeeping and reporting requirements. The owner or operator of a reciprocating compressor or centrifugal compressor subject to this section shall do the following, as applicable:
The provisions of this § 129.136 added under section 5(a)(1) and (8) of the Air Pollution Act (35 P.S. § 4005(a)(1) and (8)).
The provisions of this § 129.136 added December 9, 2022, effective December 2, 2022, 52 Pa.B. 7635.
This section cited in 25 Pa. Code § 129.131 (relating to general provisions and applicability); 25 Pa. Code § 129.132 (relating to definitions, acronyms and EPA methods); 25 Pa. Code § 129.137 (relating to fugitive emissions components); 25 Pa. Code § 129.138 (relating to covers and closed vent systems); 25 Pa. Code § 129.139 (relating to control devices); and 25 Pa. Code § 129.140 (relating to recordkeeping and reporting).