- (1) Cigarette varieties must be tested using the American Society for Testing & Materials (ASTM) International specification E2187-04, Standard Test Method for Measuring the Ignition Strength of Cigarettes or another test method approved by the OSFM consistent with ORS 476.770.
- (2) The laboratory conducting ignition propensity testing must have a quality control and assurance program. The program must ensure the testing repeatability value for all test trials used to certify a cigarette variety. The repeatability value of ignition propensity testing may not be greater than 0.19.
(3) Ignition propensity testing used in a manufacturer certification submitted to the OSFM must be conducted in a laboratory accredited under:
- (a) The International Organization for Standardization/International Electrotechnical Commission ISO/IEC 17025 Standard of International Organization for Standardization, or
- (b) A standard recognized by the OSFM consistent with ORS 476.775(b).
- (4) Refer to ORS 476.770 and 476.775 for all testing and quality control requirements.
- (5) A cigarette manufacturer may propose a test method and performance standard if OSFM determines that a variety of cigarettes cannot be tested as described in OAR 837-035-0120(1). Upon approval by the OSFM, the manufacturer may use the test method and performance standard to certify the cigarette.
Statutory/Other Authority
ORS 476
Statutes/Other Implemented
ORS 476.755 - 476.806 & 476.995
History
OSFM 3-2007, f. & cert. ef. 11-16-07
OSFM 2-2007(Temp), f. & cert. ef. 7-2-07 thru 12-28-07