(1) Within 30 days of completion of well construction, conversion, or alteration, the constructor shall permanently affix a well identification label to the wellhead in an accessible and visible location in the following manner:
- (a) For above ground completions, labels shall be at least six inches above ground surface and shall be permanently attached to the outside of the protective casing using a stainless steel band, stainless steel rivets, or screws.
(b) For flush grade completions:
- (A) Rivet or bolt the label to the inside of the monument skirting; or
- (B) Band or strap the label to the well casing; or
- (C) Insert the strap or band into the concrete in the bottom of the vault.
- (2) Identification labels may not be attached to pumps, pump equipment, water delivery lines, or well caps.
- (3) The identification label number shall be recorded on the well report at the time the report is submitted.
- (4) The well identification label shall be attached in such a manner as to be easily readable upon inspection.
- (5) Identification labels shall be furnished by the Department.
- (6) If a well identification label is already affixed to an existing well that is being altered, converted, or abandoned, the constructor shall record the identification label number on the well report.
- (7) When a well that has a well identification label on it is permanently abandoned, the well identification label shall be destroyed. The well identification label shall not be reused.
Statutory/Other Authority
ORS 536.090, ORS 537.505-537.795, ORS 536.027, ORS 536.900 & ORS 537.992
Statutes/Other Implemented
ORS 536.090, ORS 537.505-537.795, ORS 536.900 & ORS 537.992
History
WRD 5-2023, amend filed 06/22/2023, effective 07/01/2023
WRD 5-2016, f. & cert. ef. 9-6-16
WRD 7-2001, f. & cert. ef. 11-15-01