- (1) If all or a portion of the water supply well casing or the liner pipe is not removed during the abandonment of a well, the remaining casing or liner shall be thoroughly ripped or perforated. The number and size of perforations may vary, however, the perforations must be sufficient enough to allow grout to migrate outside the casing and effectively prevent the vertical movement of water. The annular space between the casing or liner and the drillhole wall shall be effectively and completely filled with cement grout applied under pressure.
- (2) Perforations are not required in the sealed interval provided proof of the original seal can be verified with the original well report. The verified seal interval shall be filled with cement grout, concrete or unhydrated bentonite.
- (3) Uncased portions of a cased well to be abandoned shall be filled in accordance with OAR 690-220-0030 through 690-220-0050.
(4) The well casing to be abandoned may be severed below land surface and removed. (See Figure 220-3.)
[ED. NOTE: To view attachments referenced in rule text, click here for PDF copy.]
Statutory/Other Authority
ORS 536.090 & 537.505 - 537.795
Statutes/Other Implemented
ORS 536.090 & 537.505 - 537.795
History
WRD 8-2023, minor correction filed 07/07/2023, effective 07/07/2023
WRD 7-2023, minor correction filed 06/26/2023, effective 06/26/2023
WRD 6-2023, minor correction filed 06/23/2023, effective 06/23/2023
WRD 3-2008, f. 12-22-08, cert. ef. 1-2-09
WRD 7-2001, f. & cert. ef. 11-15-01
WRD 8-1993, f. 12-14-93, cert. ef. 1-1-94
WRD 9-1978, f. 12-12-78, ef. 1-1-79, Renumbered from 690-063-0011
WRD 3, f. & ef. 2-18-77