Or. Admin. R. 437-007-0775
NOTE: The scope of coverage in the SAE and ISO standards referenced in OAR 437-007-0775(11) and (14) are not intended to exclude any machines included in the scope of this Division.
(1) Machines manufactured on or after July 1, 2004, that permit the operator to stand on the ground adjacent to the machine while operating the machine:
(5) An operator restraint system must be provided and used on all machines manufactured on or after July 1, 2004, and equipped with ROPS, FOPS, reinforced cabs or overhead guards. The operator restraint system must:
(b) Be maintained in an effective condition.
EXCEPTION: Use of the operator restraint system is not required when operating yarders that are stationary.
(6) The level of protection provided by any machine operator cab, protective structure or attached guarding manufactured on or after July 1, 2004, must be identified by a label. The label must:
(b) Not claim that exclusion from a standard is equivalent to compliance with that standard.
NOTE: Machines capable of 360-degree upper structure rotation are excluded from the SAE J1040 MAY94 and ISO 8082:1994 standards for ROPS. In this case, the exclusion from these standards does not allow the label on a machine capable of 360-degree upper structure rotation to state compliance with SAE J1040 MAY94 or ISO 8082:1994.
(7) Each machine used in forest activities that is manufactured on or after July 1, 2004, must have a fully enclosed cab for the operator which prevents objects from entering the cab. The fully enclosed cab must have:
(d) The overhead covering enclosed with solid material meeting the FOPS requirements of ISO 8083:1989 (11,600 Joules).
EXCEPTION 1: 437-007-0775(7)(a) is not required for the front window in machines operating in sort yards, on landings and similar prepared surfaces which are equipped with front guards meeting the SAE J1356 FEB88 requirements.
EXCEPTION 2: 437-007-0775(7)(a) and (7)(c) are not required on machines operating in mill yards.
(11) Machines capable of handling material in front of or above the deflection limiting volume (DLV), as defined by SAE J397 APR98, including yarders with cabs mounted next to the tower (boom), manufactured on or after July 1, 2004, must have a front and top guard meeting the requirements of SAE J1356:FEB88.
EXCEPTION: The rule does not apply to rubber-tired or tracked front-end loaders when equipped with buckets or forks with hold down grapple arm(s).
(12) Machines used for forest activities and those identified by SAE J1116 MAR99 that are manufactured on or after July 1, 2004, must:
(b) Comply with the requirements of OAR 437-007-0775(2) through (11).
EXCEPTION 1: This rule does not apply to high mast log stackers used exclusively to lift, transport or stack logs in sorting yards or transfer stations.
EXCEPTION 2: This rule does not apply to machines capable of 360-degree upper structure rotation that are excluded from SAE J1040:May 94 and ISO 8082:1994 standards for ROPS.
(13) Shear or deflector guarding must be:
(b) Located so they do not impede visibility and access to the cab.
EXCEPTION: This rule does not apply to rubber-tired loaders, scrapers and graders.
(14) Machines used for forest activities manufactured on or after July 1, 2004, that are excluded from the ROPS, SAE J1040:1994 or ISO 8082:1994 requirements because they are capable of 360 degree upper structure rotation must be equipped with fully enclosed cabs that meet the requirements of 437-007-0775(2) through (11). These machines must be limited to use on surfaces that are prepared, excavated or constructed of solid material with a slope of less than 20 percent unless the operator’s cab is equipped with the following additional protection:
(a) A Tip Over Protective Structure (TOPS) that meets the requirements of ISO 12117 1997:(E) with the exception of the “Formulae for the determination of energy required” In section 6.1.4 Table 1. The “Formulae for the determination of energy required” In Table 1 is changed as follows:
(c) An “Off-Boom Side Cab Guard” that complies with 437-007-0775(14)(b) when the following modifications are made to SAE J1356:FEB88:
(15) Machines used for road construction activities on prepared surfaces with a slope of less than 20 percent are not required to have front and/or top cab protective structures when the machine’s activities do not expose operators to the hazards of yarding, loading or timber falling.
[ED. NOTE: Tables referenced are available from the agency.]
ORS 654.025(2) & 656.726(4)
ORS 654.001 - 654.295
OSHA 2-2008, f. & cert. ef. 3-5-08
OSHA 5-2003, f. 6-2-03, cert. ef. 12-1-03