Or. Admin. R. 437-007-0665
(1) A competent person must carefully choose skyline, guyline and running line anchors for position and strength.
Figure 7-21 — Stump Tie Back Anchor [Figure not included. See ED. NOTE.]
(2) A competent person must inspect anchors while the operation is in progress. When necessary, anchors must be tied back or changed.
Figure 7-22 — Stump Twister Anchor [Figure not included. See ED. NOTE.]
(5) Deadman anchors must have:
(b) Deadman anchor strap or line connectors visible for inspection.
Figure 7-23 — Deadman Anchor [Figure not included. See ED. NOTE.]
(6) When a standing tree is used as an anchor:
(a) The line or strap must be attached to the base of the tree.
Figure 7-24 — Tree Tie Back Anchor [Figure not included. See ED. NOTE.]
(b) The tree must be tied back if it is within reach of any worker, the landing area, or haul road.
NOTE: In some cases, the base of a standing tree(s) that is used as an anchor may also need to be tied-back.
(c) Affected personnel must be notified of the standing tree anchor and the potential failure zone.
NOTE: See the potential failure zone requirements listed in 437-007-0927(1) through (7)
(7) The use of machines for anchoring guylines, skylines, or corner blocks must be done only under the supervision of a competent person.
Figure 7-25 — Log Loader Anchor [Figure not included. See ED. NOTE.]
(a) When determining if the machine is a suitable anchor, the competent person must consider:
(c) Machines that are used as mobile tail anchors and are stabilized with a guyline(s) must be guyed in accordance with OAR 437-007-0650(1), (2) and (3).
Figure 7-26 — Tailhold Cat Anchor [Figure not included. See ED. NOTE.]
(10) When using tipping plate anchors:
(b) The combined strength of straps or lines attached to multiple anchors must be equal in strength to the guyline, skyline, or mainline.
Figure 7-27 — Tipping Plate Anchor [Figure not included. See ED. NOTE.]
(c) Shackles used to connect straps to the anchors must be secured with a safety pin.
NOTE: This connection will not be visible for inspection.
[ED. NOTE: Figures referenced are available from the agency.]
ORS 654.025(2) & 656.726(4)
ORS 654.001 - 654.295
OSHA 2-2005, f. 5-27-05, cert. ef. 6-1-05