(1) If the Matrix Score evaluated in OAR 340-122-0330 is:
(3) A sample of contaminated soil must be collected from each separate release area and used to identify the petroleum product contamination present at that location. The Hydrocarbon Identification test specified in OAR 340-122-0218(1)(c) (NWTPH-HCID) must be used for that purpose. The NWTPH-HCID test is not required for petroleum product identification for releases from residential heating oil tanks. The results of the NWTPH-HCID test must be used to determine which analytical method or methods are required for verifying compliance with the Matrix cleanup levels. At locations where the soil is contaminated with both gasoline and diesel or other non-gasoline fraction hydrocarbons, the gasoline contamination must be shown to meet the appropriate gasoline cleanup standard and the diesel or other non-gasoline fraction contamination must be shown to meet the appropriate diesel cleanup standard.