(1) Criteria for approval. Construction permits may be issued for redundant absorption field systems to serve single family dwellings on sites that meet both of the following conditions.
- (a) The lot or parcel was created before January 1, 1974.
- (b) The lot or parcel size will not accommodate a standard system.
(2) Design criteria:
- (a) Each redundant absorption system must contain two complete absorption fields.
- (b) Each absorption field must be large enough to accommodate the projected daily sewage flow from the dwelling.
- (c) A minimum separation of 10 feet (12 feet center to center) must be maintained between absorption trenches designed to operate simultaneously, and a minimum separation of 4 feet (6 feet center to center) must be maintained between adjacent absorption trenches.
- (d) The system must be designed to alternate between the absorption fields with the use of a diversion valve or other method approved by the agent.
Statutory/Other Authority
ORS 454.625 & 468.020
Statutes/Other Implemented
ORS 454.615 & 454.775
History
DEQ 11-2004, f. 12-22-04, cert. ef. 3-1-05
DEQ 27-1994, f. 11-15-94, cert. ef. 4-1-95
DEQ 10-1981, f. & ef. 3-20-81