(1) In addition to the reporting requirements in other parts of these regulations, the licensee must report the following events if not reported under other parts of these regulations:
- (a) Source stuck in an unshielded position.
- (b) Any fire or explosion in a radiation room.
- (c) Damage to the source racks.
- (d) Failure of the cable or drive mechanism used to move the source racks.
- (e) Inoperability of the access control system.
- (f) Detection of radiation source by the product exit monitor.
- (g) Detection of radioactive contamination attributable to licensed radioactive material.
- (h) Structural damage to the pool liner or walls.
- (i) Water loss or leakage from the source storage pool, greater than the irradiator pool design parameters submitted by the licensee or applicant.
- (j) Pool water conductivity exceeding 100 microsiemens per centimeter.
- (2) The report must include a telephone report within 24 hours as described in 333-120-0710(2), and a written report within 30 days as described in 333-120-0720.