(1) Leakage levels shall be determined by measurements of microwave power density made with an instrument system which:
- (a) Reaches 90 percent of its steady-state reading within three seconds when the system is subjected to a stepped input signal;
- (b) Has a radiation detector with an effective aperture of 25 square centimeters or less as measured in a plane wave, having no dimension exceeding ten centimeters;
- (c) Is capable of measuring microwave oven leakage levels with an accuracy of plus 25 percent and minus 20 percent (plus or minus one decibel);
- (d) Has been calibrated at least within the last 12 months.
- (2) Measurements shall be made in accordance with the manufacturer’s leakage test procedures or with the microwave oven operating at its maximum output and containing a load of 275 plus or minus 15 milliliters of tap water, initially at room temperature, placed within the cavity at the center of the load-carrying surface provided by the manufacturer. The water container for the latter procedure shall be a low form 600 milliliter beaker, or substantially similar vessel, having an inside diameter of approximately 8.5 centimeters and made of an electrically nonconductive material, such as glass or plastic.
- (3) Measurements shall be made with the door fully closed, as well as with the door fixed in any other position which allows the oven to operate.
- (4) Measurements shall be made at points five centimeters or less from external surfaces of the oven.
Statutory/Other Authority
ORS 453.605 - 453.807
Statutes/Other Implemented
ORS 453.605 - 453.807
History
HD 4-1985, f. & ef. 3-20-85