(a) A violation reset shall be activated by any of the following:
- (1) Three (3) positive result startup tests within a fifteen (15) minute time frame.
- (2) A circumvention.
- (3) A retest violation.
- (4) A power violation, once power is restored to the device.
- (b) When a violation reset is activated, the device will initiate a unique audible and/or visual cue that will warn the driver that the device will enter a permanent lockout in five (5) days. This event will be uniquely recorded in the data storage system and will simultaneously start a countdown that culminates in the permanent lockout. A licensed ignition interlock technician shall remedy a permanent lockout in person unless the manufacturer has been approved for temporary lockout override issuance pursuant to O.A.C 40:50-1-3.3.
(c) Anytime a device is submitted pursuant to a violation reset the licensed ignition interlock technician shall perform a violation reset service consisting of, but not limited to:
- (1) Performing maintenance and calibration in accordance with this title, and
- (2) Retrieving all data contained in the data storage system. Proper record maintenance shall be ensured as required in this title.
Added at 27 Ok Reg 2667, eff 8-26-10
Amended at 32 Ok Reg 15369, eff 9-11-15
Amended at 36 Ok Reg 1520, eff 9-14-19
Amended at 37 Ok Reg 1001, eff 9-11-20
Amended at 40 Ok Reg 235, eff 11-1-22 (emergency)
Amended at 40 Ok Reg 841, eff 8-11-23