The light intensity shall be:
- (1) At least 108 lux (10 foot candles) at a distance of 75 cm (30 inches) above the floor, in walk-in refrigeration units and dry food storage areas and in other areas and rooms during periods of cleaning;
(2) At least 215 lux (20 foot candles):
- (A) At a surface where food is provided for consumer self-service such as buffets and salad bars or where fresh produce or packaged foods are sold or offered for consumption;
- (B) Inside equipment such as reach-in and under-counter refrigerators;
- (C) At a distance of 75 cm (30 inches) above the floor in areas used for handwashing, warewashing, and equipment and utensil storage, and in toilet rooms; and
- (3) At least 540 lux (50 foot candles) at a surface where a food employee is working with food or working with utensils or equipment such as knives, slicers, grinders, or saws where employee safety is a factor.
Added at 23 Ok Reg 2358, eff 6-25-06
Amended at 28 Ok Reg 2289, eff 11-1-11