- (a) Screening and handling. A DEQ approved procedure shall be implemented for screening wastes and handling radioactive wastes.
- (b) Detection system. Fixed radiation detection monitors, capable of detecting radiation sources as small as 0.25 millicuries of Cs137, must be installed to monitor incoming wastes.
- (c) Interlock system. Automated waste processing units must have an interlock system to automatically stop upon detection of radiation.
- (d) Hand-held detectors. Hand-held radiation detectors must be used to screen wastes when the fixed radiation detectors detect radioactive wastes.
- (e) Segregation of radioactive wastes. When radioactive wastes are detected, they must be segregated from the remainder of the wastestream for proper management.
Added at 20 Ok Reg 1151, eff 6-1-03