(a) General. Each particle accelerator facility must have appropriate monitoring equipment which:
- (1) is operable;
- (2) has been appropriately calibrated for the radiations being produced at the facility;
- (3) is tested for proper operation daily when used; and
- (4) is calibrated at least once per year and after each servicing and repair.
- (b) Radiation protection survey. A radiation protection survey shall be performed and documented by a qualified expert, when changes have been made in shielding, operation, equipment, or occupancy of adjacent areas.
- (c) High radiation areas. Radiation levels in all high radiation areas shall be continuously monitored.
- (d) Area monitors calibration. All area monitors shall be calibrated at intervals not to exceed 1 year and after each servicing and repair.
- (e) Air monitoring. Whenever conditions warrant, periodic surveys shall be made to determine the amount of airborne particulate radioactivity present.
- (f) Smear surveys. Whenever conditions warrant, periodic smear surveys shall be made to determine the degree of contamination.
- (g) Area surveys. The requirements of 252:410-11-72 apply.
- (h) Records. Permittees shall maintain records as required by 252:410-1-4 and Subchapter 3.
Added at 17 Ok Reg 1136, eff 6-1-00