N.Y. Comp. Codes R. & Regs. tit. 6, § 232-2.4
(3) External door fans. All third generation perc dry cleaning machines must be equipped with an external door fan. Fourth generation perc dry cleaning machines may only be equipped with an external door fan if installed prior to the effective date of this Subpart. External door fans must meet the following requirements:
(4) Primary emission control systems. Refrigerated condensers must:
(i) be equipped with temperature or pressure gauges to monitor performance and demonstrate compliance of the refrigerated condenser;
(5) Secondary control systems. Integral carbon adsorbers must:
(ii) reduce the perc vapor concentration in the drum to 500 ppm or less at the immediate completion of the drying cycle and prior to the activation of any fugitive emissions control system on the following dry cleaning machines without an external door fan:
(iii) reduce the perc vapor concentration in the drum to 300 ppm or less at the immediate completion of the drying cycle and prior to the activation of any fugitive emissions control system on the following dry cleaning machines:
(iv) be designed for non-contact steam, or hot air stripping, and must be stripped or desorbed, at least weekly and, in accordance with manufacturer's instructions.
(b) Perc dry cleaning machines.
(2) Existing machine requirements. Compliant perc dry cleaning machines and external door fans listed in subparagraph (i) or (ii) of this paragraph may be operated at the specified locations unless future operation is prohibited under section 232-2.3 of this Subpart.
(ii) Fourth generation perc dry cleaning machines with primary and secondary control systems that meet the requirements of paragraphs (a)(4) and (5) of this section, and external door fans that meet the requirements of paragraph (a)(3) of this section, may be operated at existing dry cleaning facilities as specified in clauses (a)-(e) of this subparagraph.
(a) Specific equipment standards and emission control specifications.