N.Y. Comp. Codes R. & Regs. tit. 6, § 219-10.2
(a) No owner or operator of a municipal or private solid waste incineration unit shall cause or allow emissions of NOx from any municipal or private solid waste incineration unit in excess of the applicable limit in table 1 of this Subpart on a 24-hour arithmetic average basis, excluding periods of start-up, shutdown, and malfunction.
Table 1 – 24-Hour Average NOx Emission Limits
| Combustion Technology | NOx Emission Limit (ppmv, dry corrected to 7% oxygen) |
|---|---|
| Mass Burn Waterwall | 150 |
| Rotary Combustor | 170 |
| Other Technologies | * |
| *See subdivision (c) of this section |
(b) No owner or operator of a municipal or private solid waste incineration facility shall cause or allow emissions of NOx from any municipal or private solid waste incineration unit in excess of the applicable limit in table 2 of this Subpart on an annual rolling average basis, excluding periods of start-up, shutdown, and malfunction.
Table 2 – Annual Average NOx Emission Limits
| Combustion Technology | NOx Emission Limit (ppmv, dry corrected to 7% oxygen) |
|---|---|
| Mass Burn Waterwall | 150 |
| Rotary Combustor | 150 |
| Other Technologies | * |
| *See subdivision (c) of this section |
(c) The owner or operator of a municipal or private solid waste incineration unit that employs a combustion technology not listed in table 1 or table 2 of this section shall develop and propose a facility specific 24-hour and annual average NOx emission limitation. A proposal prepared pursuant to this Subdivision shall consider: