N.Y. Comp. Codes R. & Regs. tit. 6, § 212-1.7
(b) Facility owners and/or operators of any emission source equipped with either a thermal or catalytic oxidizer, fixed bed carbon absorption unit or refrigerated condenser must install continuous monitors and data recorders for the applicable parameters listed in paragraphs (b)(1) through (b)(5) of this subdivision prior to start-up of a new or modified process emission source(s). Continuous monitors must be operated at all times when the associated emission control equipment is operating except during any quality assurance and routine maintenance activities. Each monitor must be operated according to a quality assurance program approved by the department. Alternative monitoring methods may be employed subject to department approval.