N.Y. Comp. Codes R. & Regs. tit. 6, § 203-7.1
(a) All owners and operators opting to comply using EPA Method 21, Volatile Organic Compound Leaks at 40 CFR Part 60, appendix A-7 (see table 1, section 200.9 of this Title), must meet the following requirements:
(3) If an analyzer other than a FID-based instrument is used, a site-specific fugitive emission definition must be developed by the owner or operator that would be equivalent to 500 ppm CH4 and VOC using a FID-based instrument. Such site-specific fugitive emission definition is subject to approval by the department.
(b) Optical gas imaging.
All owners and operators opting to comply using OGI must meet the following requirements:
(2) Calibration and maintenance procedures must comply with those recommended by the manufacturer.
(c) Alternative techniques.
The department may approve the use of an alternative technique that may be used in lieu of, or in combination with, OGI, Method 21, or other previously approved alternative methods. A proposed alternative method must be able to demonstrate that it is capable of identifying leaks and that it is at least as effective as the leak detection methods achieved using Method 21 or OGI. Owners and operators seeking approval of an alternative technique must submit the following information to the department:
(1) Describe the technology and, at a minimum, include information on:
(2) Description of use, maintenance and calibration:
(3) Process for recordkeeping: