(2) The requirements of this section do not apply to reciprocating natural gas compressors that operate fewer than 200 hours over a rolling 12 month period total, provided that the owner or operator:
(c) The compressor rod packing or seal emission flow rate through the rod packing or seal vent stack shall be measured annually by direct measurement (high volume sampling, bagging, calibrated flow measuring instrument) while the compressor is running at normal operating temperature using one of the following methods:
(e) A compressor with a rod packing or seal with a measured emission flow rate greater than 2 scfm, or a combined rod packing or seal emission flow rate greater than the number of compression cylinders multiplied by 2 scfm, shall be successfully repaired within 30 days from the date of the initial emission flow rate measurement.
(a) Applicability.