N.Y. Comp. Codes R. & Regs. tit. 21, § 509.14
(a) The following definitions refer to federally exempt linear fluorescent lamps:
(2) Cold temperature fluorescent lamp means a fluorescent lamp that is not a compact fluorescent lamp that:
(4) Impact-resistant fluorescent lamp means a fluorescent lamp that is not a compact fluorescent lamp that:
(ii) is designated and marketed for the intended application, with:
(b) marketing materials that identify the lamp as being impact-resistant, shatter-resistant, shatterproof, or shatter-protected.
(b) Standard requirements for federally exempt linear fluorescent lamps.
(2) Each of the following general service fluorescent lamps manufactured on or after January 26, 2018, shall meet or exceed the following lamp efficacy standards shown in the table:
| Lamp Type | Correlated color temperature | Min. Average lamp efficacy (lm/W) |
|---|---|---|
| 4-foot medium bipin | ≤4,500K >4,500k and ≤7,000K | 92.4 88.7 |
| 2-foot U-shaped | ≤4,500K >4,500k and ≤7,000K | 85.0 83.3 |
| 8-foot slimline | ≤4,500K >4,500k and ≤7,000K | 97.0 93.0 |
| 8-foot high output | ≤4,500K >4,500k and ≤7,000K | 92.0 88.0 |
| 4-foot miniature bipin standard output | ≤4,500K >4,500k and ≤7,000K | 95.0 89.3 |
| 4-foot miniature bipin high output | ≤4,500K >4,500k and ≤7,000K | 82.7 76.9 |
(c) Test procedures for assuring compliance with the standards established in subdivision (b) of this section.
(2) For lamps not listed in ANSI C78.81 nor in ANSI C78.901, the lamp shall be operated using the following reference ballast settings:
(iii) Eight-foot slimline lamps shall be operated using the following reference ballast settings:
(iv) Eight-foot high output lamps shall be operated using the following reference ballast settings:
(v) Four-foot miniature bipin standard output or high output lamps shall be operated using the following reference ballast settings: