(a) Amounts to be reported:
- (1) Explosives and blasting agents - any amount.
- (2) Poison gas - any amount.
- (3) Poison and irritant - any amount.
- (4) Flammable liquid - over 5 gallons inside a building and over 10 gallons outside a building.
- (5) Flammable solid - any amount
- (6) Flammable gas - over 2,000 cubic feet at standard temperature and pressure.
- (7) Nonflammable gas - over 6,000 cubic feet at standard temperature and pressure.
- (8) Oxidizer - over 50 pounds.
- (9) Organic peroxide - over 10 pounds.
- (10) Combustible liquid - over 25 gallons inside a building and over 60 gallons outside a building.
- (11) Radioactive material - any amount.
- (12) Corrosive material - over 55 gallons.
- (13) Dangerous when wet material - any amount.
- (14) Etiologic material - any amount.
An insured shall report those materials required to bear a label under regulations of the United States Department of Transportation (49 Code of Federal Regulations, parts 171 et seq.) in the quantities and amounts set out in the following table: