(e) In existing and future installations it shall not be permissible to use bars or other means to hold sidewalk doors open when the car is not at street level, unless the top and open ends are protected by a guard of wire mesh or slat construction.
(f) Guide rails.
In future installations, guide rails for both car and counterweight of sidewalk elevators shall be of steel. (See § 8-1.39.) (Sidewalk elevators located inside of building line shall be installed in accordance with freight elevator requirements.)
(g) Machinery.
The elevator machinery and sheaves shall have an ample factor of safety for the rated elevator capacity and shall be installed in a substantial manner.