N.Y. Comp. Codes R. & Regs. tit. 12, § 45-5.6
(4) Standing room—one person per each three square feet of horizontal surface area designated for such use.
(b) Exits.
(6) No turnstiles are permitted in any required means of egress.
(c) Design, construction and maintenance.
(3) Viewing stands shall be designed, constructed and maintained to resist a horizontal swaying force applied to the seats in a direction parallel to the length of the seats, of 24 pounds per linear foot of seats, and in a direction perpendicular to the length of the seats, of 10 pounds per linear foot of seats.
(d) Limit on combustible construction.
(4) If the space beneath any viewing stand is used for any purpose except exitways, the portion of the space so used shall be fully enclosed by ceilings and partitions having a fire- resistance rating of at least one hour.
(e) Openings in floor or seating space.
Openings in the floor or seating space of any permanent open air place of public assembly which exceed one-half inch in any dimension, and which are above any space occupied by the public, shall have thereunder a protective guard of one-half inch wire mesh.
(f) Seating.
(6) Rows of seats with backs shall be at least 27 inches back to back, if without backs, 22 inches. Clearance between the back of one row and the front of the row behind it shall be at least 12 inches.
(g) Aisles and crossaisles.
(7) Aisles shall be used only for passage to and from seats, and shall be kept unobstructed.
(h) Railings.
Every floor level, seat platform, bleacher seat, deck, stairway, ramp, or aisle which is more than two feet above the adjacent ground or floor level, shall have at all open sides or sections thereof a protective railing or guard at least 36 inches high.
(a) Capacity.
The capacity of viewing stands shall be the sum of the capacities listed below which are pertinent.